Notepad: On the product pages you can add product numbers with one click on the notepad symbol to the notead and later request information or quotes in one go.
0

PMK LILCO 13 Series of wide-band current transformers are capable of faithfully reproducing current
waveforms over a bandwidth which extends from the sub-hertz area to greater than 50 MHz. Whether
the requirement is to measure pulses of thousands of amps or milliamp currents in If or hf power
electronic circuitry, it will be found that PMK LILCO 13 Series current transformers are capable of
satisfying the application. Only use insulated cables to measure their current flow.

 

Specifications

Order

nummer

Output

[V/A]

RECTANGULAR PULSE SINEWAVE

Ipeak/f

[A/Hz]

DC sat.

Current

Isat [A]

Max rms

Current

Irms [A]

Peak

Current

Ipeak [A]

Droop

[%/ms]

Rise time

[ns]

I-t capability -3dB Bandwidth

No bias 

[mA s]

With bias 

[mA s]

lf [Hz] hf [MHz]
13E0050 0.05 3.3 40 660 1200 5.3 10 4.1 22 100 10000
13G0050 0.05

0.32

40 1200 2200 0.5 10 8 3 100 10000
13W0050 0.05 0.06 40 1200 2200 0.1 10 3 0.25 100 10000
13E0100 0.1 10 16 220 400 16 25 1.4 22 60 5000
13G0100 0.1 1 16 400 700 1.6 25 2.5 3 60 5000
13W0100 0.1 0.19 16 300 540 0.3 25 2 0.25 60 5000
13E0200 0.2 38 14 60 110 60 30 0.38 22 33 2500
13G0200 0.2 6.3 14 100 200 10 30 0.7 3 33 2500
13W0200 0.2 0.63 14 40 70 1 30 0.25 0.25 33 2500
13E0500 0.5 225 10 10 18 360 40 0.062 22 14 1000
13G0500 0.5 22 10 15 30 35 40 0.12 3 14 1000
13W0500 0.5 3.15 10 7 13 5 40 0.04 0.25 14 1000
13E1000 1 880 7 2.5 4,5 1400 60 0.016 22 7 500
13G1000 1 82 7 4 7 130 60 0.03 3 7 500
13W1000 1 19 7 4 7 30 60 0.02 0.25 7 500

 

Dimensions

 

 

 

→ Download Datasheet 

 

→ Download Manual 

 

 

 

The ATT10BNCS attenuator is used to extend the low frequency cut-off point by factor 10, to increase I-t (product of current and time), and to reduce droop and output factor of PMK's terminated LILCO current transformers.

 

The attenuation of the output of a terminated LILCO current transformer is achieved by reducing it's output resistance of the current transformer. The LILCO current transformer's internal shunt resistor is normally 50Ω. By applying ATT10BNCS to the output of the transformer it's output in V/A is reduced by the factor of 10.

 

For further information please contact our sales department.

product search

Since December 2018 PMK Mess- und Kommunikationstechnik GmbH is

DIN EN ISO 9001:2015 certified

 

Nuremberg, Germany

09.04. – 11.04.2024

Hall 4, Booth 4-645

Nuremberg, Germany

11.06. – 13.06.2024

Hall 7, Booth 7-157

 

Munich, Germany

12.11. -15.11.2024

We do not use any tracking cookies, but only session cookies that are necessary to perform the core functions.
Understood